Thursday, April 19, 2018

The Information about Dental Air Cleaning


The air in dental surgeries has a variety of microbiological particulates and aerosols generated from ultrasonic scaler and high-speed drills. They vary in size from 0.5 to 5 microns in diameter and can remain airborne for many hours.
Dentists and their staff can easily inhale the viruses and bacteria contained within the aerosols, with facemasks offering no protection against this fine particulate pollution. Capturing these microorganisms reduces the risk of cross-infection - for the patient, the dentist and the team.
Dental Surgeries use chemical disinfectants to decontaminate hands, surfaces and instruments. While eliminating viruses, germs and fungal spores, disinfectants often contain toxic agents such as aldehydes (formaldehyde and glutaraldehyde) or phenol. Continuous low-level exposure to aldehydes can have negative health effects, such as breathing difficulties, memory impairment, eye and skin irritation and irregular heartbeat. Toxic compounds such as isopropanol, ethanol and n-propanol can also cause irritation of the respiratory tract and the mucous membranes.
Mercury Vapours
Recent research studies have found that both dentists and their staff have a higher than average level of mercury in their body. Mercury is used in the amalgam for routine dental fillings. Mercury transforms from a solid to a gas at room temperature. The gas (which is the most easily absorbed type of mercury) can be inhaled when amalgam is placed in the mouth or removed. Mercury is highly toxic and humans should not be exposed to it.
With this news and patients becoming more health conscious, requests for amalgam removals by dental amalgamator are rising steadily. It is therefore now more important than ever, for dentists to protect themselves and their team from this harmful substance.
Dental Air Conditioning
It is now commonplace for dentists to have air-conditioning systems installed. These installation systems are, however, often a source of contamination themselves, either because they are equipped with less then adequate filtration or because they are drawing in polluted air from outside without filtering it sufficiently. Indoor air contamination can be many times greater than external conditions, and dental air cleaning is required.
Prompted by an ever growing number of dentist offices as customers, Commercial Air Filtration specifies the IQAir Dental Series which has been developed to provide a flexible, cost effective, silent and low maintenance air cleaning solution for dental practices.

Source from: http://www.chinadentalsupplier.com/2017/08/19/the-information-about-dental-air-cleaning/

Wednesday, April 18, 2018

How Does The Denture Injection System Works

As a lab owner, I am constantly looking at ways to improve the quality and service we give to the profession
When it comes to processing the dentures we as with most dental laboratories across the world use the conventional way of processing, namely, Flask and Pack and Press. Due to the growing private market, coupled with higher patient expectations, as a laboratory owner I was aware that although this time age system does work perfectly well in most instances, there were issues, i.e.: the risk of an open bite through over packing or not closing the flask adequately being one. I felt it was an issue we needed to address, to ensure the predictable results required.
Below I have listed a shortened version without all the small details of the process using the denture injection system.
The flasks have a cutaway shape into which a ‘plastic space maintainer’ is fitted, this will later be replaced with an ‘injection socket’. The base of the flask into which the waxed up denture is set, has a small hole that requires covering with wet tissue, this aids the deflasking process. Other than that the investing process for the denture is quit conventional. During investing, a wax sprue is attached that must not be more than 7mm in diameter, one to the posterior edge for upper dentures and one to each posterior border of lower dentures in a ‘Y’ shape. After applying a separator I use a silicon insulating material such as Flexistone Plus by Detax, to coverthe buccal surface of the denture up to the occlusal or incisal surface this produces a very clean and smooth surface which requires minimum finishing.
Denture Injection System

I was already aware that there were several advantages to be gained by using an injection system.
•Greater accuracy of the fit surface.
•Assured vertical dimension, due to the closed flask employed in the process.
•Increase in the density of the dentist equipment for sale; this increase should also enhance them of the denture base. It was sometimes difficult to acquire all the technical information I needed to make the right decisions. Obviously all the manufacturers want to sell their system so they may not have been always open about all the Pro’s and the Con’s of their particular systems. All of the systems on the market that I looked at required the use of special flasks for investing stage, however most were quite straight forward using plaster in the convention way to create a two part mould. I slowly narrowed down my list of available systems and at this stage approached the one manufacturer whose system I thought looked most promising.

How To Choose A Good Dental Intraoral Camera

Intraoral cameras have incredible technological features.

With LED lighting, a head that rotates from 0 to 90 degrees, and powerful magnifying capabilities (some cameras can zoom in up to 100x), your dentist can examine your mouth in extreme detail. This means he or she can make diagnoses more accurately. The office can attach these photos to your health record to make tracking any changes simple.

Additionally, because the visuals from the intraoral camera appear on the monitor as they’re taken, your dentist can discuss your oral health with you while you both see the images or footage.

intraoral cameras


How To  Choose A Good Dental Intraoral Camera

Each feature that benefits the dentist also benefits the patient—maybe even more. Your dentist understands symptoms and conditions thoroughly, but it’s often difficult to explain precisely what is happening in a patient’s mouth using just a mouth mirror, which is small and hard to see, or an x-ray image, which takes time to print and doesn’t display images clearly.

When your dentist uses an intraoral camera during your examination, however, you’re seeing exactly what he or she sees right then. Dentists can display clear, colorful images, allowing them to point out any issues and discuss them with you immediately. You’ll certainly learn a lot about your mouth! And the later you will see and understand, it can be used with the dental handpiece,too.

Many offices will print or email images for their patients so you can refer to them at home look for changes yourself. Because these images are processed immediately, it saves you time.the more confident you can be when making treatment decisions.

Friday, September 1, 2017

The Information about Chairside Sandblasting

An advance in adhesive dentistry has resulted in sandblasting, to increases micro-retention, being performed as a routine procedure. Instead of wearing a path from the patient’s chair to the office lab to clean excess cement from a patient’s temporary or loosened permanent crown ,or for sandblasting the fitting surface of a crown, bridge inlay or veneer, the procedure is a half- turn away, thanks to the new breed of sandblasters and hookup options.

The uninterrupted patient/doctor exchange is especially beneficial with anxious adult patients – no need to cut the reassuring golf story short for a trip down the hall, leaving the patient alone. Standard hookup kits allow, with a simple male disconnect, access to the dental equipment's air source through the female port. Many dentists have sandblasters with quick disconnects in every operatory, and these space- efficient wonders tuck easily into a drawer.

The Deldent MiniBlaster ® even boast adaptors for standard 4-hole dental handpiece ports,or even for your favorite Kavo®, Sirona® or W&H® High speed handpiece port, for a blasting procedure – just pop on the adaptor and activate the sandblaster with your regular foot control, And how about the air quality?

The old dust collection methods are fast disappearing as dentists perform more and more chairside sandblasting. You’ve heard of them as the homemade variety, consisting of a discarded packaging box of gallon plastic milk carton with three handcuts holes.

Learning over the nearest trash can, much to the dismay of office staff, best of all, throwing open a window and blasting away (weather permitting). Times have changed and the new waves of dust collectors not only keep the air clean, but they look great, too – they’re high-tech looking, lightweight and simple to operate and empty. No fancy installation, either- they simply plug into the nearest outlet.

Best of all, the new breed of dust collectors are scaled to fit comfortably on an operatory countertop without without getting in the way, and without compromising user comfort or efficiency. They’re designed with clean, pleasing lines to fit into today’s contemporary dental office design and decor.

Tuesday, July 11, 2017

Doing Wisdom Teeth Removal

The wisdom teeth are the last set of permanent molars to grow out of the gumline. They usually appear between the ages of 17 to 25, and in some people do not appear at all. They can be the cause of problems for many people. If there is not enough room or space in the mouth for normal growth, they may not erupt properly and can cause discomfort. They can grow at abnormal angles, and may even remain trapped in the jawbone. Because of the position in the mouth, they may be hard to reach for proper care, and can be the cause of painful cavities that result from tooth decay.

Many people, and even some dentists may suggest pre-mature removal as a preventative measure. It is believed that they have gained the moniker “wisdom teeth” in the 17th Century. It appears that the attribution results from the fact that they appear later in life, when adults are supposed to have gained more wisdom.

The procedure was easily done in the office of your dentist or surgeon with dental equipment, and depending on your tolerance for pain, you can opt to having all of your wisdom teeth removed at the same time. With new research, and advantages being made in medical and dental care, the messages being delivered by your teeth removal dentist appears to be changing.

The normal procedure for this involves the dentist to apply a numbing agent and then inject the area with a local anesthetic. If you are really afraid the dentist can give you some nitrous oxide to help calm your nerves. This is a gas that you inhale through an oxygen style mask. The dentist will start the mask off with pure oxygen and then slowly add the nitrous to the oxygen until you have received an amount that will allow you to relax. When you are relaxed you will be less likely to move and cause yourself undo pain.

After the shots of local anesthetic have been administered there will be a period of time when you will be waiting for the anesthetic to take effect. If the dental care providers know that you are extremely frightened they will more than likely have someone stay with you while they wait for the medicine and brushless micro motor to take effect. Periodically they will come in and check your mouth to see if you are still able to feel pain in the area where they will be working.

Wisdom teeth removal will require the dental care provider to use extractors that resemble a type of plier. The extractor will be designed to grip the tooth securely so the dentist can pull it out of your mouth. You will feel some pressure as the tooth is pulled free. The dentist may seem to be turning or twisting the tooth. That is what they need to do in order to break the roots free.

Friday, June 30, 2017

Some Information about Compressed Air System

According to PneumaticTips, it’s important to remember that, if you consider the overall cost of ownership of a compressed air system, assuming a ten-year life for the system, the purchase cost only accounts for about 12% of the total. Furthermore, 76% of the cost of owning a compressed air system comes in the form of electricity bills.
To put this in perspective, if you continuously run a 100-hp compressor at full power, you will spend $74,000 a year in energy costs, assuming a rate of 10 cents per kWh.

Therefore, if you are assessing the value of your compressed air system and making your decision in purely economic terms, you need to keep the total cost of ownership in the forefront of your mind. While the cost of repairs may be significantly less than the cost of replacing your system, ask yourself if you’re keeping a system working that’s actually costing you more in the long run by operating less efficiently.

These costs come in many different forms. First, as compressors age, the costs of repairs increase. That’s why you should carefully consider any repair that costs over 50% of the cost of a comparable replacement. But you also need to consider the operational inefficiencies and the subsequent costs of an older compressor. Because of how inefficient some older models are, you may be wasting as much money on energy costs as you would spend on a new dental compressor.

Many operational malfunctions can be traced back to the power source. Are there issues with the point of connection between your compressor and the electric grid? Additionally, improper lubricant levels can contribute to poor operation. When was the last time you checked and adjusted the oil levels in your system?

If you are experiencing excessive noise or knocking while the compressor is running, loose bearings, flywheels, belts or defective crankcases are also possible culprits. If you can isolate the source of the noise, you can either make the small adjustments necessary or at least guide a repair technician in the right directions, potentially saving you money on otherwise costly repairs.

Wednesday, June 21, 2017

Choosing a Right Dental Compressor

The most popular compressors are positive displacement compressors, which work by filling a chamber with air and then reducing volume. Positive displacement compressors include reciprocating, rotary screw and rotary vane compressors. Although reciprocating compressors are the most widely available on the market, rotary compressors are most useful in industrial environments.

Air compressors are a substantial investment for business owners, so the process of purchasing one requires consideration of many factors.

considerations should help you choose the right air compressor system for your business:

    Buying a dental compressor that’s too small can waste time, due to waiting for pressure to build up, and using a compressor that’s too big can waste resources.

    Select an air compressor that provides enough airflow. A compressor’s airflow is measured in cubic feet per minute (CFM). The air compressor’s CFM output should be greater than the operational CFM requirement and less than the maximum CFM output. A half-inch wrench, for example, requires 5 CFM at 90 pounds per square inch (psi), which means the CFM output should be greater to ensure proper performance with the tool. A good rule of thumb is to add 30 percent to the determined CFM number. Adding all the air tools to be used in a work day, however, may result in an inflated CFM number.

     If you need to stop using a tool to wait for pressure to build, the compressor may be too small. Note that continuous-use tools will have higher CFM requirements than intermittent-use tools. Higher pressures and volumes will naturally require increased horsepower, electrical components and larger pumping systems. When considering a compressor, actual cubic feet per minute (ACFM) will provide a more accurate measurement of usable air.

    Know your work environment. Knowing this will help determine whether the drive system should be an electric motor or a gasoline engine. Electric motors are less expensive and require less maintenance. Gasoline engines offer increased portability.

    Determine the size of the compressor tank. This depends on the overall nature of the usage. A small tank should prove sufficient for quick, concentrated bursts of usage. Sustaining longer periods of use will require a larger tank.

    Determine the tools needed. If you know which tools you need for your business, it will help determine how many psi the compressor should be able to provide.

    Determine the horsepower needed. This information will ensure the compressor can produce enough air. A machine with high horsepower but low CFM will run hot in a shorter service life.

    Consider your control systems. Start/stop systems are helpful for work that doesn’t require continuous air. Constant speed control is ideal if expecting more than six to eight starts per hour. Dual control uses an auxiliary valve that permits a choice between start/stop and constant speed.

    Use the right protection. If using a compressor outside, it will need protection against water and extreme temperatures. Cast-iron construction will ensure added reliability and durability.

    Consider other features in addition to tank size, pressure and airflow. Stainless steel finger valves will eliminate corrosion. Oil-monitoring devices prevent damage caused by low oil levels. One-piece connecting rods eliminate many internal adjustments. Keep in mind that fewer parts will reduce maintenance costs.